11838
MRL Z&Y Header Line Replacement
Cleanaway Waste Management Ltd
Melbourne Regional Landfill
1100-1152 Christies Rd, Ravenhall, Victoria 3023 Australia

Complete
Header Line Replacement

Run Energy will:

  • Install lateral header line
  • Install leachate line
  • Install air line
  • Install Knock-Out-Pot (KOP)
  • Install Pump
  • Modify in accordance with attached drawings 

Details:

Item Quantity/Size Installation Notes
Lateral header line 200  m x 250 mm PN8
  • Surface lay the lateral header line between well station 2Y and isolation valve HSP12
  • Expose, cut and cap existing 355 mm lateral header line adjacent to well station 2Y
  • Route to be confirmed with CWY onsite
Leachate line 200 m  x 90 mm PN10
  • To be installed between well station 2Y and leachate line adjacent to isolation valve HSP2
  • Install riser at the KOP location
  • Route to be confirmed with CWY onsite
Air line 200 m x  63 mm PN12.5
  • To be installed between well station 2Y and leachate line adjacent to isolation valve HSP2
  • Install riser at the KOP location
  • Route to be confirmed with CWY onsite
KOP 1 x 500  mm 
  • To be installed at the lowest point of the lateral header line
Pump 1 x 4" bottom fill pump
  • To be installed in the KOP
  • Connect to air and leachate risers 

 

Note;

  • The existing lateral header line has over 10 m of fill over it preventing it being exposed and repaired

 

  • No variations
No. Description Scheduled Billing Milestone Complete Complete is checked in the LFG Construction Daily Log
1    
2    
3    
4    
5    
6    
7    
8    
9    
10    
 
Date Issued
Equipment Type
Equipment Serial ID
 
11838  (41 Record records) 
10-OCT-2019 EF Welder 170603320
10-OCT-2019 Butt Welder 225mm 840015
10-OCT-2019 Personal Gas Monitor KA415-1043983
10-OCT-2019   GCBET-1086332
10-OCT-2019 Personal Gas Monitor KA416-1073321
07-OCT-2019 Personal Gas Monitor KA415-1043983
07-OCT-2019 Butt Welder 315mm 18848
07-OCT-2019 Personal Gas Monitor KA416-1073321
07-OCT-2019 Butt Welder 315mm 18848
07-OCT-2019 Personal Gas Monitor KA415-1043983
07-OCT-2019 Personal Gas Monitor KA416-1073321
07-OCT-2019   GCBET-1086332
07-OCT-2019   GCBET-1086332
07-OCT-2019 Butt Welder 225mm 840015
07-OCT-2019 Butt Welder 225mm 840015
07-OCT-2019 EF Welder 170603320
07-OCT-2019 EF Welder 170603320
03-OCT-2019 Personal Gas Monitor KA416-1073321
03-OCT-2019 Butt Welder 315mm 18848
03-OCT-2019   GCBET-1086332
03-OCT-2019 EF Welder 170603320
03-OCT-2019 Personal Gas Monitor KA415-1043983
03-OCT-2019 Butt Welder 225mm 840015
02-OCT-2019 Butt Welder 225mm 840015
02-OCT-2019 Personal Gas Monitor KA416-1073321
02-OCT-2019 EF Welder 170603320
02-OCT-2019 Personal Gas Monitor KA415-1043983
02-OCT-2019   GCBET-1086332
02-OCT-2019 Butt Welder 315mm 18848
01-OCT-2019 Personal Gas Monitor KA416-1073321
01-OCT-2019 Butt Welder 225mm 840015
01-OCT-2019 Butt Welder 315mm 18848
01-OCT-2019 EF Welder 170603320
01-OCT-2019 Personal Gas Monitor KA415-1043983
01-OCT-2019   GCBET-1086332
30-SEP-2019   GCBET-1086332
30-SEP-2019 Butt Welder 225mm 840015
30-SEP-2019 Butt Welder 315mm 18848
30-SEP-2019 Personal Gas Monitor KA415-1043983
30-SEP-2019 Personal Gas Monitor KA416-1073321
30-SEP-2019 EF Welder 170603320
 
Date
Team Lead
Work Summary
 
No Daily Log records found
Yes
 
Date
Site Name
Type
Title
Run Job Number
CQA Report
Job Number
Drawing
 
21-NOV-2023 Melbourne Regional Landfill Job GCS As-Built As built 11838 11838 Dwg
30-MAR-2020 Melbourne Regional Landfill Job GCS As-Built 20190925_MRL_SITE ASBUILT_REV Y 11838 11893 Dwg
No
No
No
Yes
Unable to display report. You do not have sufficient permission.
Russell Clarke
Dean Wilson
Show fields from Show fields from Show fields from a related table
Report Name *
Description
Reports and Charts Panel
Each table has a panel listing its reports and charts, organized in groups.
Please wait while your new report is saved...
Field label
Column heading override
Justification
What does auto mean?
Fields in:

Fields to Extract:

Name for the new table:
Items in the new table are called:

When you bring additional fields into a conversion, Quickbase often finds inconsistencies. For example, say you're converting your Companies column into its own table. One company, Acme Corporation, has offices in New York, Dallas and Portland. So, when you add the City column to the conversion, Quickbase finds three different locations for Acme. A single value in the column you're converting can only match one value in any additional field. Quickbase needs you to clean up the extra cities before it can create your new table. To do so, you have one of two choices:

  • If you want to create three separate Acme records (Acme-New York, Acme-Dallas and Acme-Portland) click the Conform link at the top of the column.
  • If the dissimilar entries are mistakes (say Acme only has one office in New York and the other locations are data-entry errors) go back into your table and correct the inconsistencies—in this case, changing all locations to New York. Then try the conversion again.

Read more about converting a column into a table.