MRL Leachate Collection System Installation
Cleanaway Waste Management Ltd
Melbourne Regional Landfill
1100-1152 Christies Rd, Ravenhall, Victoria 3023 Australia

Complete
 
Date
Document Type
Document
 
Issued for Construction Drawing Set  (1 Document)  
25-JUN-2020 Issued for Construction Drawing Set Doc
Leachate Collection System Installation

Run Energy will:

  • Weld and lay leachate line
  • Weld and lay air line
  • Install air and leachate risers
  • Install leachate sump headworks
  • Install in accordance with the attached design drawing:
    • Leachate Collection System - Air/Leachate Installation - Dwg 015-DN-002 

Details:

Item Quantity/Size Installation Notes
Leachate sump headworks 2 x 450 mm PN16
  • Install on leachate sumps in cell 4C1
  • Refer to the attached design drawing for approximate locations 
    • sump ID's to be advised 
Leachate line 530 m x 110 mm PN10
  • Lay and weld on cell perimeter from leachate sump LP37 to the leachate sump adjacent to the air compressor
    • refer to the design drawing for the location
    • no allowance for route clearance or preparation
Air line 530 m x  63 mm PN16
  • Lay and weld on cell perimeter from leachate sump LP37 to the leachate sump adjacent to the air compressor
    • refer to the design drawing for the location
    • no allowance for route clearance or preparation
Air and leachate risers 2 x 63 mm PN16
  • Install at each of the leachate sumps
  • Complete valve train and frame
    • refer to the design drawing for the location

Leachate sump headworks

2 x 450 mm 
  • Install at each leachate sump
  • Complete with 160 mm capped stub offtake spigot and 90 mm capped pipe offtake spigot
    • the cap is also fitted with a 50 x 1 1/2" threaded socket
  • Sump ID's to be advised 
  • No variations
Pump Supply

Run Energy will supply:

Item Quantity/Unit
Airwell 150mm x 1m (BF6010) pump on skids 2
Solar controller 2
Cable kit 2 x 35 m
Seal cap 2 x 140 mm ID
Air regulator/cycle counter 2
Exhaust pipe/support pole  2
Air pump kit 2
Liquid level tube arrangement 2
  • No variations
Pump Installation

Run Energy will:

  • Assemble pump offsite
  • Install pump
  • Install liquid level tube arrangement
  • Install stainless steel and communication supporting cables
  • Install control box complete with air regulator and cycle counter
  • Install seal caps
  • Install exhaust/support pole
  • Connect to leachate collection system
  • Commission pump

Details:

Item Quantity/Details
Pump 2 x Airwell 150mm x 1m (BF6010) pump on skids
Connection to leachate collection system Air and leachate risers at each location
  • No variations
No. Description Scheduled Billing Milestone Complete Complete is checked in the LFG Construction Daily Log
1 Install 2 x 450mm leachate sump headworks Day 1 - Day 2   Yes  
2 Weld, lay and install 530m x 110mm leachate line Day 3 - Day 6   Yes  
3 Lay and install 530m x 63mm airline Day 7   Yes  
4 Install 2 x 63mm air & leachate risers Day 8   Yes  
5 Complete 2 x 450mm leachate sump headworks Day 9 - Day 10    
6 GPS and clean site (100% payment: $26,946) Day 11 Yes    
7    
8    
9    
10    
 
Date Issued
Equipment Type
Equipment Serial ID
 
12082  (40 Record records) 
02-JUL-2020 Generator: Gasoline GCBCT-1807167
02-JUL-2020 EF Welder 30171-SB
02-JUL-2020 Laser Level 255431
02-JUL-2020 Personal Gas Monitor KA416-1073217
01-JUL-2020 EF Welder 180602575
01-JUL-2020 Generator: Gasoline GCBCT-1807167
01-JUL-2020   GCBCT-2085011
01-JUL-2020 EF Welder 30171-SB
01-JUL-2020 Laser Level 255431
01-JUL-2020 Personal Gas Monitor KA416-1073217
25-JUN-2020 EF Welder 30171-SB
25-JUN-2020 Generator: Gasoline GCBCT-1807167
25-JUN-2020 Laser Level 255431
25-JUN-2020 Personal Gas Monitor KA413-1087514
25-JUN-2020 Personal Gas Monitor KA416-1073217
25-JUN-2020 Personal Gas Monitor KA416-1067974
24-JUN-2020 EF Welder 30171-SB
24-JUN-2020 Generator: Gasoline GCBCT-1807167
24-JUN-2020 Laser Level 255431
24-JUN-2020 Personal Gas Monitor KA413-1087514
24-JUN-2020 Personal Gas Monitor KA416-1073217
24-JUN-2020 Personal Gas Monitor KA416-1067974
23-JUN-2020 Personal Gas Monitor KA413-1087514
23-JUN-2020 Personal Gas Monitor KA416-1073217
23-JUN-2020 Personal Gas Monitor KA416-1067974
23-JUN-2020 Generator: Gasoline GCBCT-1807167
23-JUN-2020 Laser Level 255431
23-JUN-2020 EF Welder 30171-SB
22-JUN-2020 Generator: Gasoline GCBCT-1807167
22-JUN-2020 EF Welder 30171-SB
22-JUN-2020 Laser Level 255431
22-JUN-2020 Personal Gas Monitor KA416-1073217
22-JUN-2020 Personal Gas Monitor KA416-1067974
22-JUN-2020 Personal Gas Monitor KA413-1087514
17-JUN-2020   GCBET-1086332
17-JUN-2020 EF Welder 30171-SB
17-JUN-2020 Personal Gas Monitor KA413-1087514
17-JUN-2020 Personal Gas Monitor KA416-1067942
15-JUN-2020 EF Welder 30858-SB
15-JUN-2020   565075
 
Date
Team Lead
Work Summary
 
12082 - MRL Leachate Collection System Installation  (9 Daily Log records) 
02-JUL-2020 Nicholas Barned Tie in air line to existing system near LP37 - check for leaks on both air and leachate lines - all good
01-JUL-2020 Nicholas Barned Install remaining 120metres of 110mm & 63mm lines to second sump
Install air & leachate risers at second sump
Tie in leachate line - unable to tie in air line as missing 63mm tee
Load up remaining 110mm pipe and transport back to Gas plant with trailer
Track excavator back to Gas plant - clean tracks ready for off hire
26-JUN-2020 Nicholas Barned Nil works onsite - hire equipment stood down for the day
25-JUN-2020 Nicholas Barned Cut in tees and Install air and leachate risers at first sump
Extend 63mm & 110mm pipes to reach tie in point near LP37
Prepare pipe for tie in
Weld 118m of 110 & 63mm ready for next section to second sump - drag up onto top of batter ready for install once Fabtech/Shamrock have completed liner/sump works
Organise fittings for next weeks works and ensure all parts are there
24-JUN-2020 Nicholas Barned Lay and weld 400 metres of 110mm & 63mm along edge of batter
Install bends around concrete sump area
23-JUN-2020 Nicholas Barned Uncoil 5 x 63mm pipes & 5 x 110mm pipes
Delay in getting into works area in the morning due to not having an escort from Shamrock 
Delay in getting back for lunch and back again due to same issues
Discussion with Shamrock & Cleanaway on exact location of where pipes are to be laid
Obtain radio with programmed silent channel from Shamrock to minimise delays with escorts.
22-JUN-2020 Nicholas Barned Boral Induction onsite for Nick, John & Cesare
Shamrock Site Induction for Nick, John & Cesare
Transport 5 x 110mm Coils, 5 x 63mm Coils, 4 x 63mm 6mtr lengths & 10 x 110mm 6mtr lengths over to work area using excavator
Travel to factory and pick up fittings & unistrut 
Travel back to MRL with Pipe trailer
20-JUN-2020   Delivery of pipe - site too wet to unload at works area - unload near Gas Plant compound
17-JUN-2020   Drive direct to mrl 0645 on site
Locate leachate line
110mm  leachate line connection reconnected to right line
Clamp off exiting line 
Re route and weld in new line and socket to reconnect section.
Approximately  3 mtrs of 110mm used, for repair, 1 x 110 elbow, 3x110 sockets 1x110 tee used

** Apparently this is warranty work 
Deb created NB Variation from oos works


Yes
 
Date
Site Name
Type
Title
Run Job Number
CQA Report
Job Number
Drawing
 
03-JUL-2020 Melbourne Regional Landfill Job GCS As-Built Leachate Collection System Installation 12082 12082 Dwg
No
No
No
No
Russell Clarke
Dean Wilson
Show fields from Show fields from Show fields from a related table
Report Name *
Description
Reports and Charts Panel
Each table has a panel listing its reports and charts, organized in groups.
Please wait while your new report is saved...
Field label
Column heading override
Justification
What does auto mean?
Fields in:

Fields to Extract:

Name for the new table:
Items in the new table are called:

When you bring additional fields into a conversion, Quickbase often finds inconsistencies. For example, say you're converting your Companies column into its own table. One company, Acme Corporation, has offices in New York, Dallas and Portland. So, when you add the City column to the conversion, Quickbase finds three different locations for Acme. A single value in the column you're converting can only match one value in any additional field. Quickbase needs you to clean up the extra cities before it can create your new table. To do so, you have one of two choices:

  • If you want to create three separate Acme records (Acme-New York, Acme-Dallas and Acme-Portland) click the Conform link at the top of the column.
  • If the dissimilar entries are mistakes (say Acme only has one office in New York and the other locations are data-entry errors) go back into your table and correct the inconsistencies—in this case, changing all locations to New York. Then try the conversion again.

Read more about converting a column into a table.